Hutachiona hweHuman Papillomavirus (Mhando 28) Kuongororwa kweGenotyping

Tsananguro pfupi:

Kit iyi inoshandiswa pakuona nucleic acid yemhando makumi maviri nemasere dzehuman papillomavirus (HPV6, 11, 16, 18, 26, 31, 33, 35, 39, 40, 42, 43, 44, 45, 51, 52, 53, 54, 56, 58, 59, 61, 66, 68, 73, 81, 82, 83) muweti yevarume/yevakadzi uye masero emukadzi akabviswa muchibereko, zvichipa nzira dzekubatsira pakuongorora nekurapa hutachiona hweHPV.


Ruzivo rweChigadzirwa

Matagi eChigadzirwa

Zita rechigadzirwa

HWTS-CC013-Human Papillomavirus (Mhando 28) Kit yekuona majini (Fluorescence PCR)

HWTS-CC016A-Human Papillomavirus yakaomeswa nechando (Mhando 28) Kit yekuona majini (Fluorescence PCR)

Epidemiology

Gomarara remumuromo wechibereko ndeimwe yemabundu anonyanya kuipa enhengo dzekubereka dzevakadzi. Ongororo dzakapfuura dzakaratidza kuti hutachiona hunoramba huripo uye hutachiona hwakawanda hwepapillomavirus yemunhu ndeimwe yezvikonzero zvakakosha zvegomarara remumuromo wechibereko. Parizvino, kuchine kushaikwa kwenzira dzinozivikanwa dzekurapa HPV dzinoshanda, saka kuongororwa nekukurumidza uye kudzivirira HPV yemumuromo wechibereko ndiwo makiyi ekudzivirira gomarara. Kugadzira nzira iri nyore, chaiyo uye inokurumidza yekuongorora chirwere kunokosha zvikuru mukuongororwa kwegomarara remumuromo wechibereko.

Chiteshi

Chinovhara maitiro ekuita FAM VIC/HEX ROX CY5
HPV Genotyping Reaction Buffer 1 16 18 / Kudzora kwemukati
HPV Genotyping Reaction Buffer 2 56 / 31 Kudzora kwemukati
HPV Genotyping Reaction Buffer 3 58 33 66 35
HPV Genotyping Reaction Buffer 4 53 51 52 45
HPV Genotyping Reaction Buffer 5 73 59 39 68
HPV Genotyping Reaction Buffer 6 6 11 83 54
HPV Genotyping Reaction Buffer 7 26 44 61 81
HPV Genotyping Reaction Buffer 8 40 43 42 82

Magadzirirwo ehunyanzvi

Kuchengetera Mvura: ≤-18℃
Nguva yekuzorora mwedzi gumi nemiviri
Rudzi rwemuenzaniso Chinokwesha wemuromo wechibereko, Chinokwesha weti kubva kuvanhukadzi
Ct ≤28
CV ≤5.0%
LoD Makopi 300/mL
kujeka Mhedzisiro yese inenge isina kunaka kana kit ichishandiswa kuona sampuli dzisiri dzechokwadi dzine maitiro akasiyana nayo, kusanganisira ureaplasma urealyticum, chlamydia trachomatis yenzira yekubereka, candida albicans, neisseria gonorrhoeae, trichomonas vaginalis, mold, gardnerella nedzimwe mhando dzeHPV dzisina kuvharwa nekit.
Zvishandiso Zvinoshanda Sisitimu yePCR yeApplied Biosystems 7500 Real-Time

Maitiro eApplied Biosystems 7500 PCR Systems Inokurumidza Munguva Yechokwadi

QuantStudio®Masisitimu mashanu ePCR enguva chaiyo

Masisitimu ePCR eSLAN-96P Enguva Yechokwadi

Chiedza cheKufambisa Mwenje®Masisitimu ePCR e480 Enguva Yechokwadi

Masisitimu ekuona maPCR eLineGene 9600 Plus Real-Time

MA-6000 Chaiyo-Nguva Yekuyera Kupisa Kwemhepo

Sisitimu yePCR yeBioRad CFX96 Yenguva Yechokwadi

Sisitimu yePCR yeBioRad CFX Opus 96 Yenguva Yechokwadi

Kufamba Kwebasa

Sarudzo 1.

Zvinokurudzirwa kubvisa ma reagents: Macro & Micro-Test Sample Release Reagent (HWTS-3005-8)

Sarudzo yechipiri.

Zvinokurudzirwa kuti munhu abvise mabhakitiriya: Macro & Micro-Test Viral DNA/RNA Kit (HWTS-3004-32, HWTS-3004-48, HWTS-3004-96) uye Macro & Micro-Test Automatic Nucleic Acid Extractor (HWTS-3006C, HWTS-3006B)


  • Yakapfuura:
  • Zvinotevera:

  • Nyora meseji yako pano woitumira kwatiri