Mhando makumi maviri nesere dzeHuman Papilloma Virus (16/18 Typing) Nucleic Acid

Tsanangudzo Pfupi:

Iyi kit inokodzera in vitro qualitative kuonekwa kwe28 marudzi ehuman papilloma viruses (HPV) (HPV6, 11, 16, 18, 26, 31, 33, 35, 39, 40, 42, 43, 44, 45, 51, 52, 53, 54, 56, 58, 59, 61, 66, 68, 73, 81, 82, 83) nucleic acid muweti yemurume / yevakadzi uye masero echikadzi echikadzi.HPV 16/18 inogona kutaipa, mhando dzakasara hadzigoni kunyatsotaipa, zvichipa nzira yekubatsira kuongororwa uye kurapwa kwehutachiona hweHPV.


Product Detail

Product Tags

Product name

HWTS-CC006A-28 Mhando dzeHuman Papilloma Virus (16/18 Typing) Nucleic Acid Detection Kit (Fluorescence PCR)

Epidemiology

Chirwere chegomarara remuchibereko nderimwe remamota anouraya anonyanyozivikanwa emudumbu remukadzi.Ongororo dzakaratidza kuti HPV inoramba ichibata utachiona uye zvirwere zvakawanda ndicho chimwe chezvikonzero zvikuru zvegomarara remuchibereko.Parizvino, mishonga inozivikanwa inobudirira ichiri kushaikwa kwegomarara remuromo wechibereko rinokonzerwa neHPV, saka kukasika kuwanikwa pamwe nekudzivirirwa kweutachiona hweHIV hunokonzerwa neHPV ndiyo kiyi yekudzivirira gomarara remuchibereko.Izvo zvakakosha zvikuru kumisikidza yakapusa, yakananga uye nekukurumidza etiology diagnostic test yekiriniki yekuongororwa uye kurapwa kwegomarara rechibereko.

Channel

Reaction Mix Channel Type
PCR-Mix1 FAM 18
VIC(HEX) 16
ROX 31, 33, 35, 39, 45, 51, 52, 56, 58, 59, 66, 68
CY5 Kudzora Kwemukati
PCR-Mix2 FAM 6, 11, 54, 83
VIC(HEX) 26, 44, 61, 81
ROX 40, 42, 43, 53, 73, 82
CY5 Kudzora Kwemukati

Technical Parameters

Storage Mvura: ≤-18℃
Sherufu-hupenyu 12 mwedzi
Type Type Cervical Swab, Vaginal Swab, Weti
Ct ≤28
CV <5.0%
LoD 300Makopi/mL
Zvishandiso Zvishandiso Applied Biosystems 7500 Chaiyo-Nguva PCR Systems
Applied Biosystems 7500 Fast Real-Time PCR Systems
Vadivelu Comedy QuantStudio®5 Chaiyo-Nguva PCR Systems
SLAN-96P Chaiyo-Nguva PCR Systems
LightCycler®480 Chaiyo-Nguva PCR system
LineGene 9600 Plus Chaiyo-Nguva PCR Detection System
MA-6000 Chaiyo-Nguva Quantitative Thermal Cycler
BioRad CFX96 Chaiyo-Nguva PCR System
BioRad CFX Opus 96 Chaiyo-Nguva PCR System

Kuyerera Kwebasa

Inokurudzirwa kuburitsa reagent: Macro & Micro-Test Viral DNA/RNA Kit (HWTS-3017-50, HWTS-3017-32, HWTS-3017-48, HWTS-3017-96) (iyo inogona kushandiswa neMacro & Micro-Test Automatic Nucleic Acid Extractor (HWTS-3006C, HWTS-3006B)) by Jiangsu Macro & Micro-Test Med-Tech Co., Ltd. Wedzera 200μL yesaline yakajairwa kumisazve pellet mudanho 2.1, uye ipapo kubviswa kunofanirwa kuitwa zvinoenderana kune mirairo yekushandisa iyi reagent yekubvisa.Iyo yakakurudzirwa elution vhoriyamu i80μL.
Recommended extraction reagent: QIAamp DNA Mini Kit (51304) kana Macro & Micro-Test Viral DNA/RNA Column (HWTS-3020-50).Wedzera 200μL yesaline yakajairwa kumisazve pellet mudanho 2.1, uye ipapo kubviswa kunofanirwa kuitwa zvinoenderana nemirairo yekushandisa iyi yekubvisa reagent.Iyo yakatorwa sample vhoriyamu yemasampuli ese ari 200μL, uye yakakurudzirwa elution vhoriyamu i100μL.