Mhando makumi maviri nesere dzeHuman Papilloma Virus (16/18 Typing) Nucleic Acid
Product name
HWTS-CC006A-28 Mhando dzeHuman Papilloma Virus (16/18 Typing) Nucleic Acid Detection Kit (Fluorescence PCR)
Epidemiology
Chirwere chegomarara remuchibereko nderimwe remamota anouraya anonyanyozivikanwa emudumbu remukadzi.Ongororo dzakaratidza kuti HPV inoramba ichibata utachiona uye zvirwere zvakawanda ndicho chimwe chezvikonzero zvikuru zvegomarara remuchibereko.Parizvino, mishonga inozivikanwa inobudirira ichiri kushaikwa kwegomarara remuromo wechibereko rinokonzerwa neHPV, saka kukasika kuwanikwa pamwe nekudzivirirwa kweutachiona hweHIV hunokonzerwa neHPV ndiyo kiyi yekudzivirira gomarara remuchibereko.Izvo zvakakosha zvikuru kumisikidza yakapusa, yakananga uye nekukurumidza etiology diagnostic test yekiriniki yekuongororwa uye kurapwa kwegomarara rechibereko.
Channel
Reaction Mix | Channel | Type |
PCR-Mix1 | FAM | 18 |
VIC(HEX) | 16 | |
ROX | 31, 33, 35, 39, 45, 51, 52, 56, 58, 59, 66, 68 | |
CY5 | Kudzora Kwemukati | |
PCR-Mix2 | FAM | 6, 11, 54, 83 |
VIC(HEX) | 26, 44, 61, 81 | |
ROX | 40, 42, 43, 53, 73, 82 | |
CY5 | Kudzora Kwemukati |
Technical Parameters
Storage | Mvura: ≤-18℃ |
Sherufu-hupenyu | 12 mwedzi |
Type Type | Cervical Swab, Vaginal Swab, Weti |
Ct | ≤28 |
CV | <5.0% |
LoD | 300Makopi/mL |
Zvishandiso Zvishandiso | Applied Biosystems 7500 Chaiyo-Nguva PCR Systems Applied Biosystems 7500 Fast Real-Time PCR Systems Vadivelu Comedy QuantStudio®5 Chaiyo-Nguva PCR Systems SLAN-96P Chaiyo-Nguva PCR Systems LightCycler®480 Chaiyo-Nguva PCR system LineGene 9600 Plus Chaiyo-Nguva PCR Detection System MA-6000 Chaiyo-Nguva Quantitative Thermal Cycler BioRad CFX96 Chaiyo-Nguva PCR System BioRad CFX Opus 96 Chaiyo-Nguva PCR System |
Kuyerera Kwebasa
Inokurudzirwa kuburitsa reagent: Macro & Micro-Test Viral DNA/RNA Kit (HWTS-3017-50, HWTS-3017-32, HWTS-3017-48, HWTS-3017-96) (iyo inogona kushandiswa neMacro & Micro-Test Automatic Nucleic Acid Extractor (HWTS-3006C, HWTS-3006B)) by Jiangsu Macro & Micro-Test Med-Tech Co., Ltd. Wedzera 200μL yesaline yakajairwa kumisazve pellet mudanho 2.1, uye ipapo kubviswa kunofanirwa kuitwa zvinoenderana kune mirairo yekushandisa iyi reagent yekubvisa.Iyo yakakurudzirwa elution vhoriyamu i80μL.
Recommended extraction reagent: QIAamp DNA Mini Kit (51304) kana Macro & Micro-Test Viral DNA/RNA Column (HWTS-3020-50).Wedzera 200μL yesaline yakajairwa kumisazve pellet mudanho 2.1, uye ipapo kubviswa kunofanirwa kuitwa zvinoenderana nemirairo yekushandisa iyi yekubvisa reagent.Iyo yakatorwa sample vhoriyamu yemasampuli ese ari 200μL, uye yakakurudzirwa elution vhoriyamu i100μL.