Chlamydia Trachomatis, Neisseria Gonorrhoeae uye Trichomonas vaginalis
Product name
HWTS-UR041 Chlamydia Trachomatis, Neisseria Gonorrhoeae uye Trichomonas vaginalis Nucleic Acid Detection Kit (Fluorescence PCR)
Epidemiology
Chlamydia trachomatis (CT) imhando yeprokaryotic microorganism iyo yakanyanya parasitic mumasero eukaryotic.Chlamydia trachomatis yakakamurwa kuva AK serotypes maererano serotype nzira.Urogenital tract infections inonyanya kukonzerwa ne trachoma biological variant DK serotypes, uye varume vanonyanya kuratidzwa se urethritis, iyo inogona kusunungurwa pasina kurapwa, asi vazhinji vavo vanova vasingaperi, nguva nenguva vachiwedzera, uye vanogona kusanganiswa ne epididymitis, proctitis, nezvimwewo.
Channel
FAM | Chlamydia trachomatis |
ROX | Neisseria gonorrhoeae |
CY5 | Trichomonal vaginitis |
VIC/HEX | Kudzora Kwemukati |
Technical Parameters
Storage | -18 ℃ |
Sherufu-hupenyu | 12 mwedzi |
Type Type | Mukadzi cervical swab,Mukadzi swab yemukadzi,Urethral swab yemurume |
Ct | ≤38 |
CV | <5% |
LoD | 400Makopi/mL |
Zvakananga | Iko hakuna kuyambuka-reactivity nemamwe STD hutachiona hwehutachiona kunze kwekuonekwa kwemhando yetest kit, yakadai seTreponema pallidum, Mycoplasma hominis, Mycoplasma genitalium, Herpes simplex virus type 1, Herpes simplex virus type 2, Candida albicans, nezvimwe. |
Zvishandiso Zvishandiso | Applied Biosystems 7500 Chaiyo-Nguva PCR System Applied Biosystems 7500 Fast Real-Time PCR Systems Vadivelu Comedy QuantStudio®5 Chaiyo-Nguva PCR Systems SLAN-96P Chaiyo-Nguva PCR Systems LightCycler®480 Chaiyo-Nguva PCR system LineGene 9600 Plus Chaiyo-Nguva PCR Detection System MA-6000 Chaiyo-Nguva Quantitative Thermal Cycler BioRad CFX96 Chaiyo-Nguva PCR System BioRad CFX Opus 96 Chaiyo-Nguva PCR System |
Kuyerera Kwebasa
Sarudzo 1.
Recommended extraction reagent: Pipette 1mL yesampuli kuti iongororwe kune 1.5mL yeDNase/RNase-isina centrifuge chubhu, centrifuge pa12000rpm kwemaminetsi matatu, rasa supernatant uye chengeta kunaya.Wedzera 200µL yesaline yakajairwa kumvura yekumisa zvakare.Macro & Micro-Test General DNA/RNA Kit (HWTS-3019-50, HWTS-3019-32, HWTS-3019-48, HWTS-3019-96) (iyo inogona kushandiswa neMacro & Micro-Test Automatic Nucleic Acid Extractor (HWTS-3006C, HWTS-3006B)) neJiangsu Macro & Micro-Test Med-Tech Co., Ltd. Kubviswa kunofanira kuitwa maererano nemurairo wekushandisa.Iyo yakatorwa vhoriyamu yemuenzaniso ndeye 200µL, uye yakakurudzirwa elution vhoriyamu i80µL.
Sarudzo 2.
Inokurudzirwa yekubvisa reagent: Nucleic Acid Extraction kana Purification Kit (YDP302).Kubvisa kunofanira kuitwa zvakasimba maererano nemurairo wekushandisa.Iyo yakakurudzirwa elution vhoriyamu i80µL.