Mhando Nhanhatu dzeGenitourinary Tract Infection Pathogen Nucleic Acid Detection Kit (Fluorescence PCR)
Zita rechigadzirwa
Mhando Pfumbamwe dzeJenitourinary Tract Infection Pathogen Nucleic Acid Detection Kit(Fluorescence PCR)
Epidemiology
Zvirwere zvepabonde (STIs) zvichiri chimwe chezvinhu zvinotyisa zvikuru kune veruzhinji pasi rosekuchengetedzeka kwehutano, sezvo zvichigona kutungamira mukushaya mbereko, kuberekwa nguva isati yakwana, bundu rinomuka, nezvimwe zvakasiyana-siyanaMatambudziko akakomba. Utachiona hwezvirwere zvepabonde hwakasiyana-siyana, kusanganisira mabhakitiriya, mavhairasi,Chlamydia, Mycoplasma, uye spirochetes. Mhando dzakajairika dzinosanganisira Chlamydiatrachomatis, Ureaplasma urealyticum, Ureaplasma parvum, Mycoplasma hominis,hutachiona hweherpes simplex rudzi 1 (HSV-1), Neisseria gonorrhoeae, hutachiona hweherpes simplex rudzi2 (HSV-2), Mycoplasma genitalium, uye Trichomonal vaginitis.
Magadzirirwo ehunyanzvi
| Kuchengetera | ≤ -18℃ |
| Nguva yekuzorora | mwedzi gumi nemiviri |
| Rudzi rwemuenzaniso | Weti, chirauro chemurume cheurethra, chirauro chemukadzi chemuromo wechibereko, chirauro chechikadzi chemukadzi |
| CV | <5.0% |
| LoD | Muganho weKuona (LoD): LoD yekiti yekuona CT, NG, UU, UP, HSV1, HSV2, Mg, uye TV i400Copies/mL; LoD yekiti yekuona Mh i1000Copies/mL. |
| Kunyatsojeka | Hapana kusangana kwezvirwere zvakafanana nezvirwere zvepabonde. |
| Zvishandiso Zvinoshanda | Rudzi I: Applied Biosystems 7500 Real-Time PCR System, Applied Biosystems 7500 Fast Real-Time PCR Systems, QuantStudio®5 Real-Time PCR Systems, SLAN-96P Real-Time PCR Systems (Hongshi Medical Technology Co., Ltd.), LightCycler®480 Real-Time PCR system, LineGene 9600 Plus Real-Time PCR Detection System (FQD-96A, Hangzhou Bioer technology) uye MA-6000 Real-Time Quantitative Thermal Cycler (Suzhou Molarray Co., Ltd.). Rudzi rwechipiri: Eudemon TM AIO800 (HWTS-AIO800) yakagadzirwa neJiangsu Macro & Micro-Test Med-Tech Co., Ltd. |
Chiteshi
Kufamba kwebasa:
Rudzi I:
Rudzi rwechipiri:
Ma reagents anoda asi haana kupihwa:
Rudzi I:
Macro & Micro-Test General DNA/RNA Kit (HWTS-3019) (inogona kushandiswa neMacro & Micro-Test Automatic Nucleic Acid Extractor (HWTS-3006B,HWTS-3006C)) naJiangsu Macro & Micro-Test Med-Tech Co., Ltd., Macro &Micro-Test Viral DNA/RNA Column (HWTS-3022), Sample Preservation Solution(HWTS-3015) yakagadzirwa neJiangsu Macro & Micro-Test Med-Tech Co., Ltd..
Rudzi rwechipiri:
Kit yeMacro & Micro-Test Viral DNA/RNA (HWTS-3019-8), MuenzanisoMhinduro Yekuchengetedza (HWTS-3015) yakagadzirwa neJiangsu Macro & Micro-Test Med-Tech Co.,Ltd.Zvinoshandiswa zvinodiwa asi hazvipihwe:1.5mL yechubhu yeDNase/RNase isina centrifuge,Mazano asina DNase/RNase, centrifuge yedesktop, musanganiswa weoscillation yedesktop.