Kiti yekuona zvirwere zveSTI Multiplex 7

Tsananguro pfupi:

Kodhi Yechigadzirwa

HWTS-UR012

Kushandiswa Kwakarongwa

Kit iyi yakagadzirirwa kuona zvirwere zvinowanzoonekwa zvehutachiona hwemudumbu, zvinosanganisira Neisseria gonorrhoeae (NG), Chlamydia trachomatis (CT), Ureaplasma urealyticum (UU), Herpes Simplex Virus Type 1 (HSV1), Herpes Simplex Virus Type 2 (HSV2), Mycoplasma hominis (Mh), Mycoplasma genitalium (Mg) mumasero emudumbu evarume nemadzimai.


Ruzivo rweChigadzirwa

Matagi eChigadzirwa

Zita rechigadzirwa

Kiti yekuona zvirwere zveSTI Multiplex

Epidemiology

Utachiona hwepabonde (STI) huri kuramba huri chimwe chezvinhu zvinotyisidzira hutano hweveruzhinji pasi rose, izvo zvinogona kukonzera kusabereka, kuberekwa nguva isati yakwana, kubuda kwebundu, uye matambudziko akasiyana-siyana akakomba. Kune mhando dzakawanda dzezvirwere zveSTI, zvinosanganisira mabhakitiriya, mavhairasi, chlamydia, mycoplasma, uye spirochetes. NG, CT, UU, HSV 1, HSV 2, Mh, Mg zvakanyanya kuwanda.

Magadzirirwo ehunyanzvi

Kuchengetera ≤ -18℃
Nguva yekuzorora mwedzi gumi nemiviri
Rudzi rwemuenzaniso Kubuda kwemudumbu, Kubuda kwemumuromo wechibereko
CV <5.0%
LoD Muganho weKuona (LoD): LoD yekiti yekuona CT, NG, UU, HSV1, HSV2 uye Mg i400Copies/mL; LoD yekiti yekuona Mh i1000Copies/mL.
Kunyatsojeka Hapana kusangana kwezvirwere zvakafanana nezvirwere zvepabonde.
Zvishandiso Zvinoshanda

Applied Biosystems 7500 Real-Time PCR Systems, Applied Biosystems 7500 Fast Real-Time PCR Systems, QuantStudio®5 Real-Time PCR systems, SLAN® -96P Real-Time PCR Systems, LightCycler® 480 Real-Time PCR system, LineGene 9600 Plus Real-Time PCR Detection System (FQD-96A, Hangzhou Bioer technology), MA-6000 Real-Time Quantitative Thermal Cycler (Suzhou Molarray Co., Ltd.), BioRad CFX96 Real-Time PCR System, BioRad CFX Opus 96 Real-Time PCR System nezvimwe.

Chiteshi

Reaction Buffer Chinangwa Mutori wenhau Mudzimisi
Chishandiso cheNjodzi cheKugadzirisa 1 CT FAM hapana
UU VIC (HEX) hapana
Mh ROX hapana
HSV1 CY5 hapana
Kugadzirisa Matambudziko Enjoyiti 2 NG FAM hapana
HSV2 VIC (HEX) hapana
Mg ROX hapana
IC CY5 hapana

Kufamba Kwebasa

670e945511776ae647729effe7ec6fa

MaReagents anoda asi haana kupihwa

Macro & Micro-Test Sample Release Reagent (HWTS-3005-8); Macro & Micro-Test General DNA/RNA Kit (HWTS-3017) (inogona kushandiswa neMacro & Micro-Test Automatic Nucleic Acid Extractor (HWTS-EQ011)) neJiangsu Macro & Micro-Test Med-Tech Co., Ltd. Kubviswa kwesainzi kunofanirwa kuitwa zvichienderana neIFU.

Zvinoshandiswa zvinodiwa asi hazvipihwe:1.5mL yechubhu yeDNase/RNase isina centrifuge, DNase/RNase isina Tips, desktop entrifuge, desktop oscillation mixer.


  • Yakapfuura:
  • Zvinotevera:

  • Nyora meseji yako pano woitumira kwatiri