Herpes Simplex Virus Type 2 Nucleic Acid

Tsanangudzo Pfupi:

Iyi kit inoshandiswa pakuonekwa kwemhando yeherpes simplex virus type 2 nucleic acid mumurume urethral swab uye cervical cervical swab samples.


Product Detail

Product Tags

Product Name

HWTS-UR007A-Herpes Simplex Virus Type 2 Nucleic Acid Detection Kit (Fluorescence PCR)

Chinangwa Kushandiswa

Iyi kit inoshandiswa pakuonekwa kwemhando yeherpes simplex virus type 2 nucleic acid mumurume urethral swab uye cervical cervical swab samples.

Epidemiology

Herpes Simplex Virus Type 2 (HSV2) hutachiona hwedenderedzwa hwakagadzirwa ne tegument, capsid, musimboti, uye envelope, uye ine kaviri-yakasungwa mutsara DNA.Utachiona hweHerpes hunogona kupinda mumuviri kuburikidza nekubata zvakananga kana kusangana pabonde neganda uye mucous membranes, uye yakakamurwa kuva yekutanga uye inodzokororwa.Utachiona hwehutachiona hunonyanya kukonzerwa neHSV2, varwere vechirume vanoratidzwa semaronda epenile, uye varwere vechikadzi vanoratidzwa semuromo wekervical, vulvar, uye maronda emukadzi.Zvirwere zvekutanga zvegenital herpes virus kazhinji hutachiona hwehutachiona, kunze kweashoma emunharaunda herpes ane mucous membrane kana ganda, mazhinji ayo asina pachena zviratidzo zvekiriniki.Genital herpes utachiona hune hunhu hwehupenyu hwese hutakura hutachiona uye nyore kudzoka, uye vese varwere nevatakuri ndivo tsime rehutachiona hwechirwere.MuChina, serological positive rate yeHSV2 inenge 10.80% kusvika 23.56%.Nhanho yehutachiona hweHSV2 inogona kukamurwa kuita hutachiona hwekutanga uye hutachiwana huchidzokororwa, uye vangangoita 60% yevarwere vane HSV2 vanodzoka zvakare.

Epidemiology

FAM: Herpes Simplex Virus Type 2 (HSV2)·

VIC (HEX): Kudzora Kwemukati

 

PCR Amplification Conditions Setting

Danho

Cycles

Tembiricha

Nguva

UnganidzaFluorescentSiignalskana Kwete

1

1 Cycle

50 ℃

5 mins

No

2

1 Cycle

95℃

10mins

No

3

40 Cycles

95℃

15secs

No

4

58℃

31secs

Ehe

Technical Parameters

Storage  
Liquid

≤-18℃ Murima

Sherufu-hupenyu 12 mwedzi
Type Type

Mukadzi cervical swab, Male urethral swab

Ct

≤38

CV

≤5.0%

LoD 50Makopi/maitiro
Zvakananga

Iko hakuna kuyambuka-reactivity nemamwe hutachiona hweSTD, seTreponema pallidum, Chlamydia trachomatis, Ureaplasma urealyticum, Mycoplasma hominis, Mycoplasma genitalium uye nezvimwe.

Zvishandiso Zvishandiso

Inogona kuenderana neyakajairwa fluorescent PCR zviridzwa pamusika.

Applied Biosystems 7500 Chaiyo-Nguva PCR Systems

Applied Biosystems 7500 Fast Real-Time PCR Systems

QuantStudio®5 Chaiyo-Nguva PCR Systems

SLAN-96P Chaiyo-Nguva PCR Systems

LightCycler®480 Chaiyo-Nguva PCR system

LineGene 9600 Plus Chaiyo-Nguva PCR Detection System

MA-6000 Chaiyo-Nguva Quantitative Thermal Cycler

BioRad CFX96 Chaiyo-Nguva PCR System

BioRad CFX Opus 96 Chaiyo-Nguva PCR System.

Kuyerera Kwebasa

d7dc2562f0f3442b31c191702b7ebdc


  • Zvakapfuura:
  • Zvinotevera:

  • Nyora meseji yako pano ugotitumira