Hepatitis B Virus RNA
Product name
HWTS-HP007 Hepatitis B Virus RNA Nucleic Acid Detection Kit (Fluorescence PCR)
Epidemiology
Quantitative kuonekwa kwemazinga eHBV-RNA muserum anogona kutarisa zviri nani chiyero cheHBV cccDNA muhepatocytes, uye panguva imwechete kudzivisa kukonzera kukanganisa kukuru kune varwere.Izvo zvakakosha zvikuru pakubatsira kuongororwa kwehutachiona hweHepatitis B (HBV) hutachiona uye nekutarisa kushanda uye kufanotaura kubviswa kwezvinodhaka kweNAs antiviral therapy muvarwere veCHB.
Channel
FAM | HBV-RNA |
ROX | Kudzora Kwemukati |
Technical Parameters
Storage | ≤-18℃ |
Sherufu-hupenyu | 9 mwedzi |
Type Type | serum |
Tt | ≤42 |
CV | ≤5.0% |
LoD | 100 makopi / mL |
Zvakananga | Mhedzisiro yekukanganisa mhedzisiro inoratidza kuti hapana mhedzisiro pakutemerwa kweHBV RNA kana kuwanda kwebilirubin muserum isingapfuuri 168.2μmol/mL, kuwanda kwehemoglobin inogadzirwa nehemolysis hakupfuuri 130g/L, uye kuwanda kweropa lipids hakusi kupfuura 65mmol/mL;hapana migumisiro pakugadzirisa kweHBV RNA apo huwandu hweIgG muserum haisi kupfuura 5mg / mL.Mhedzisiro yekuongorora mhedzisiro inoratidza kuti hapana kupindirana pakati pekiti iyi nemamwe mavhairasi kana mabhakitiriya akaonekwa nenucleic acid mumasampuli eropa (utachiona hwehepatitis C, human cytomegalovirus, epstein-barr virus, human immunodeficiency virus, hepatitis A, syphilis. , human herpes virus type 6, herpes simplex virus type 1, herpes simplex virus type 2, furuwenza A, propionibacterium acnes, staphylococcus aureus, candida albicans) uye genome dzevanhu;mushure mekunge varwere vatora lamivudine, telbivudine, adefovir dipivoxil uye entecavir, apo hutachiwana hwehutachiwana hwehutachiwana hwehutachiwana huri mumuviri huri pamusoro pehuwandu hweLoD hwekiti, kititi inogona kunyatsoonekwa. |
Zvishandiso Zvishandiso | Applied Biosystems 7500 Chaiyo-Nguva PCR SystemApplied Biosystems 7500 Fast Real-Time PCR Systems SLAN-96P Chaiyo-Nguva PCR Systems (Hongshi Medical Technology Co., Ltd.) |
Kuyerera Kwebasa
Sarudzo 1.
Viral DNA/RNA Isolation Kit (NA007-2) by GenMag Biotechnology Co., Ltd. Matanho chaiwo ekubvisa ndapota nyatsoteverai bhuku rekuraira.
Macro & Micro-Test General DNA/RNA Kit (HWTS-3017-50, HWTS-3017-32, HWTS-3017-48, HWTS-3017-96) (iyo inogona kushandiswa neMacro & Micro-Test Automatic Nucleic Acid Extractor (HWTS-3006C, HWTS-3006B)) naJiangsu Macro & Micro-Test Med-Tech Co., Ltd. Kubviswa kunofanirwa kuitwa maererano nebhuku rekuraira, iyo yakatorwa sample vhoriyamu i200μL, uye yakakurudzirwa elution vhoriyamu ndeye 80μL.