Utachiona hweHepatitis A
Zita rechigadzirwa
Kiti yeHWTS-HP005 Hepatitis A Virus Nucleic Acid Detection Kit (Fluorescence PCR)
Epidemiology
Utachiona hweHepatitis A (HAV) ndiyo inonyanya kukonzera chirwere chehepatitis chinokonzerwa nehutachiona. Utachiona uhwu ihutachiona hweRNA hune tsinga imwe chete uye huri murudzi rweHepadnavirus rwemhuri yePicornaviridae. Utachiona hweHepatitis A, hunonyanya kutapurirwa nefecal-mouth route, husingapiswi nekupisa, acids, uye zvakawanda zvinonyungudutsa, hunogona kurarama kwenguva yakareba mushellfish, mumvura, muvhu, kana mugungwa [1-3]. Hunotapurirwa nekudya kana mvura yakasviba, kana kuti hunotapurirwa zvakananga kubva kumunhu kuenda kumunhu. Zvekudya zvine chekuita neHAV zvinosanganisira oysters neclams, mastrawberry, raspberries, mablueberries, madate, miriwo yemashizha matema, uye madomasi akaomeswa zvishoma [4‒6].
Chiteshi
| FAM | HAV nucleic acid |
| ROX | Kudzora Kwemukati |
Magadzirirwo ehunyanzvi
| Kuchengetera | ≤-18℃ |
| Nguva yekuzorora | Mvura: mwedzi 9, Lyophilized: mwedzi 12 |
| Rudzi rwemuenzaniso | Serum/chitsiko |
| Tt | ≤38 |
| CV | ≤5.0% |
| LoD | Makopi maviri/μL |
| Kunyatsojeka | Shandisa makits aya kuyedza mamwe mavhairasi ehepatitis akadai sehepatitis B, C, D, E, enterovirus 71, coxsackie virus, Epstein-Barr virus, norovirus, HIV uye human genome. Hapana cross-reactivity. |
| Zvishandiso Zvinoshanda | Sisitimu yePCR yeApplied Biosystems 7500 Real-Time Maitiro eApplied Biosystems 7500 PCR Systems Inokurumidza Munguva Yechokwadi QuantStudio®Masisitimu mashanu ePCR enguva chaiyo Masisitimu ePCR eSLAN-96P Munguva Yechokwadi (Hongshi Medical Technology Co., Ltd.) Sisitimu yePCR yeLightCycler®480 Yenguva Yechokwadi LineGene 9600 Plus Real-Time PCR Detection System (FQD-96A, Hangzhou Bioer technology), MA-6000 Real-Time Quantitative Thermal Cycler Sisitimu yePCR yeBioRad CFX96 Yenguva Yechokwadi Sisitimu yePCR yeBioRad CFX Opus 96 Yenguva Yechokwadi |
Kufamba Kwebasa
Sampuro dzeSerum
Sarudzo 1.
Macro & Micro-Test General DNA/RNA Kit (HWTS-3017-50, HWTS-3017-32, HWTS-3017-48, HWTS-3017-96) uye Macro & Micro-Test Automatic Nucleic Acid Extractor (HWTS-3006C, HWTS-3006B). Inofanira kutorwa zvichienderana nemirayiridzo. Vhoriyamu yekudzikisa inokurudzirwa i80µL.
Sarudzo yechipiri.
TIANamp Virus DNA/RNA Kit (YDP315-R) yakagadzirwa neTiangen Biotech (Beijing) Co., Ltd. Inofanira kutorwa zvichienderana nemirayiridzo. Vhoriyamu yemuenzaniso yakatorwa i140μL. Vhoriyamu yekubvisa inokurudzirwa i60μL.
2.Mienzaniso yeChitsiko
Macro & Micro-Test General DNA/RNA Kit (HWTS-3017-50, HWTS-3017-32, HWTS-3017-48, HWTS-3017-96) uye Macro & Micro-Test Automatic Nucleic Acid Extractor (HWTS-3006C, HWTS-3006B). Inofanira kutorwa zvichienderana nemirayiridzo. Vhoriyamu yekudzikisa inokurudzirwa i80µL.